Benchtop Dental Lab Digital Centrifugal Casting Machine Centrifuge 4000RPM
- £10 Off Over £150
- £20 Off Over £300
- £30 Off Over £500
- £50 Off Over £800
- £60 Off Over £1000
- £80 Off Over £1500
- Enjoy Discount at Checkout!
- Valid Till October 15th, 2024
- Note:No coupon code needed, please place order directly!
Benchtop Dental Lab Digital Centrifugal Casting Machine Centrifuge 4000RPM
The desktop low-speed centrifuge is a conventional laboratory centrifuge, which is widely used in scientific research, education and production departments such as cosmetology, biology, chemistry, and medicine. The low-speed benchtop centrifuge has a maximum speed of 4000R/MIN, which is suitable for radioimmunoassay identification and separation of cells and large particles.
2. Technical indicators
model | Maximum speed | capacity | Maximum relative centrifugal force | Timing range | power supply |
TD4C | 4000rpm | 5/7ml×8 | 2200xg | 99min | AC220V/110V 50HZ/60HZ |
4000rpm | 10/15ml×8 | 2200xg | 99min | AC220V/110V 50HZ/60HZ | |
4000rpm | 20ml×8 | 2200xg | 99min | AC220V/110V 50HZ/60HZ | |
4000rpm | 50ml×4 | 2200xg | 99min | AC220V/110V 50HZ/60HZ | |
4000rpm | 15ml×12 | 2200xg | 99min | AC220V/110V 50HZ/60H |
3. Safety instructions
1. Before working, put the hollow tube evenly into it, and run the machine at the highest speed for 1-2 minutes. Only when there is no abnormality can it work.
2. Do not touch the rotating head.
3. It is strictly forbidden to operate the rotor under unbalanced loading.
4. If the wire or plug is damaged or the electrical equipment malfunctions, it should be repaired by professionals. The use of electrical equipment not recommended by the manufacturer will cause certain quality problems.
5. Do not use in direct sunlight.
6. The electrical rated parameters of the power socket provided by the user should be greater than the electrical rated parameters of the machine, and good grounding measures should be taken.
7. Do not place this machine next to a high-temperature heating element.
8. It is strictly forbidden to rotate the machine while it is running.
9. Strong impact on this machine is strictly prohibited.
10. To replace the fuse, pull out the plug from the socket first.
4. Instructions for use
1. The working room is neat and clean, dry and well ventilated.
2. The inner cavity and rotor should be wiped clean before starting up.
3. Put the previously weighed test tube into the centrifuge hole.
4. Close the centrifuge lid. Set the timing time and turn on the power switch.
5. Adjust the speed control button to increase to the required speed.
6. After the work is finished, turn off the power switch and cut off the power supply.
Wipe the inner cavity and rotor, close the centrifuge cover;
Greeloy® GU-P206 Portable Dental Unit with Scaler + Curing Light + Dental Handpiece Kit
does this come with a slow speed hand piece too?
12/04/2024 by Sara
DASK Dental Dentium Sinus Implant Elevation Drill Stopper Hand Instrument Kit
Item arrived fast and in good condition. I received it fairly quickly!
18/01/2024 by Dr.Kaulin
Woodpecker Mini Ray Portable Dental X-ray Unit Handheld Xray Machine Digital Imaging System
Awesome !!! 100% woodpecker original. It works well and arrived earlier than was expected! Thanks
18/01/2024 by Kendle
GREELOY Dental Delivery Unit Mobile Cart Self-contained Air Compressor+ Scaler+ LED Curing Light
As promised, the seller shipped it with Fedex and it arrived much sooner than anticipated. I am so pleased with this purchase.
14/12/2023 by Dr.Stern
Greeloy 350L/min Portable Mobile Dental Suction Unit Vacuum Pump with Strong Suction GSM-300
Good quality! It has great suction power.This is my second dental suction unit from your site, thanks your quick response and excellent service.
14/12/2023 by Dr.Ganecka